Dongguan Forever Co.,Ltd is the manufacture of the china origin cheap UV stablized PC polycarbonate Granules Polymer Resin
Availability:
Quantity:
  • 8202C-XH

  • Forever

8202C-XH is a specially designed PA6 injection molding material with a modified crystalline structure and low viscosity. It offers increased strength, stiffness, heat resistance, and performance under load, making it ideal for various applications. This material is available in heat stabilized and pigmented versions to suit different needs. Additionally, 8202C-XH has enhanced cycling capabilities while maintaining its properties and chemical resistance. It is commonly used in applications such as furniture casters, gears, window hardware, fittings, electrical insulators, bushings, valves, relays, wiring devices, and other electrical components.


General

Form

 Resin Pellets

Feature

 Medium-Low Viscosity


 Crystalline

 Homopolymer


 Chemical Resistant

Excellent Processability  


Ec 1907/2006 (Reach)

Bushings                            Fittings                              Furniture

Usage                                          Electrical Engineering      Gear Wheels                      Electrical

 Valves/Valve Parts

Physical                                                                                Nominal Value                                       Test Method

Density, dry                                                                          1.13 g/cm³                                              ASTM D792;ISO

1183

Dry: Molding Shrinkage - Flow(3.18 mm)                           0.90 %                                                    No Standard

Dry: Water Absorption

24 hr                                                                                    1.6 %                                                       ASTM D570

24 hr;23 °C                                                                            1.6 %                                                       ISO 62

Dry: Water Absorption, Saturation

9.3 %                                                    ASTM D570

23 °C                                                                                    9.3 %                                                       ISO 62

Dry: Water Absorption, Equilibrium

50% RH                                                                               2.6 %                                                       ASTM D570

50% RH;23 °C                                                                      2.6 %                                                        ISO 62

Dry: Rockwell Hardness, R-Scale                                         120                                                         ASTM D785

Mechanical                                                                            Nominal Value                                     Test Method

Dry: Tensile Modulus                                                                                                                          ISO 527-2

-40 °C                                                                                   4090 MPa

23 °C                                                                                     3700 MPa

80 °C                                                                                     750 MPa

120 °C                                                                               550 MPa

150 °C                                                                                 445 MPa


Condition: Tensile Modulus(23 °C)

1360 MPa

ISO 527-2

Dry: Tensile Strength, Yield

-40 °C

80 °C

23 °C

121 °C

23 °C

120 °C

150 °C

137 MPa

40.0 MPa

90.0 MPa

30.0 MPa

88.0 MPa

30.0 MPa

25.0 MPa

ASTM D638;ISO 527-2

ASTM D638;ISO

527-2

ASTM D638

ASTM D638

ISO 527-2

ISO 527-2

ISO 527-2

Condition: Tensile Strength, Yield

-40 °C

80 °C

23 °C

121 °C

23 °C

120 °C

142 MPa

30.0 MPa

48.0 MPa

25.0 MPa

43.0 MPa

25.0 MPa

ASTM D638;ISO 527-2

ASTM D638;ISO

527-2

ASTM D638

ASTM D638

ISO 527-2

ISO 527-2

Dry: Tensile Strength, Break

-40 °C

23 °C

80 °C

121 °C

130 MPa

90.0 MPa

35.0 MPa

25.0 MPa

ASTM D638

Condition: Tensile Strength, Break

-40 °C

23 °C

80 °C

121 °C

80.0 MPa

70.0 MPa

30.0 MPa

20.0 MPa

ASTM D638

Dry: Tensile Elongation, Yield

-40 °C

80 °C

121 °C

23 °C

3.0 %

25 %

27 %

4.0 %

ASTM D638

ASTM D638

ASTM D638

ASTM D638;ISO 527-2


Condition: Tensile Elongation, Yield

-40 °C

80 °C

121 °C

23 °C

3.0 %

25 %

30 %

22 %

ASTM D638

ASTM D638

ASTM D638

ASTM D638;ISO 527-2

Dry: Tensile Elongation, Break

-40 °C

23 °C

80 °C

121 °C

5.0 %

12 %

> 100 %

> 100 %

ASTM D638

Condition: Tensile Elongation, Break

-40 °C

23 °C

80 °C

121 °C

3.0 %

> 100 %

> 100 %

> 100 %

ASTM D638

Dry: Nominal Tensile Strain at Break

-40 °C

23 °C

80 °C

120 °C

5.0 %

7.0 %

> 100 %

> 100 %

ISO 527-2

Condition: Nominal Tensile Strain at Break

-40 °C

23 °C

80 °C

120 °C

3.0 %

> 50 %

> 100 %

> 100 %

ISO 527-2

Dry: Flexural Modulus

-40 °C

23 °C

65 °C

90 °C

121 °C

23 °C

3370 MPa

3170 MPa

600 MPa

440 MPa

385 MPa

2800 MPa

ASTM D790

ASTM D790

ASTM D790

ASTM D790

ASTM D790

ISO 178


Condition: Flexural Modulus

-40 °C

23 °C

4200 MPa

970 MPa

ASTM D790

Dry: Flexural Strength

-40 °C

23 °C

65 °C

121 °C

23 °C

183 MPa

110 MPa

30.0 MPa

21.0 MPa

95.0 MPa

ASTM D790

ASTM D790

ASTM D790

ASTM D790

ISO 178

Condition: Flexural Strength

-40 °C

23 °C

168 MPa

42.0 MPa

ASTM D790

Dry: Charpy Notched Impact Strength(23 °C)

3.5 kJ/m²

ISO 179

Dry: Charpy Unnotched Impact Strength(23 °C)

No Break

ISO 179

Dry: Notched Izod Impact

-40 °C

23 °C

32 J/m

48 J/m

ASTM D256

Izod Notched Impact: condition

-40 °C

23 °C

21 J/m

170 J/m

ASTM D256

Dry: Drop Weight Impact Strength(23 °C)

122 J

Internal Method


Thermal

Nominal Value

Test Method

Dry: Deflection Temperature Under Load, Unannealed

0.45 MPa

1.8 MPa

0.45 MPa

1.8 MPa

190 °C

75.0 °C

165 °C

65.0 °C

ASTM D648

ASTM D648

ISO 75-2/B

ISO 75-2/A

Dry: Peak Melting Temperature

220 °C

ASTM D3418;ISO 3146

Dry: CLTE - Flow

8.1E-5 cm/cm/°C

ASTM E831

Dry: RTI Elec

0.71 mm

1.5 mm

3 mm

6 mm

125 °C

125 °C

125 °C

125 °C

UL 746

Dry: RTI Imp

0.71 mm

1.5 mm

3 mm

6 mm

65.0 °C

75.0 °C

75.0 °C

75.0 °C

UL 746

Dry: RTI Str

0.71 mm

1.5 mm

3 mm

6 mm

65.0 °C

85.0 °C

85.0 °C

85.0 °C

UL 746

Dry: Flame Rating

0.71 mm

1.5 mm

3 mm

6 mm

V-2

V-2

V-2

V-2

UL 94


Electrical

Nominal Value

Test Method

Dry: Volume Resistivity



1.5 mm

> 1.0E+15 Ohms ·cm

> 1.0E+15 Ohms ·cm

ASTM D257

IEC 60093

Dry: Dielectric Strength, Method A, Short-Time(1.5 mm)

30 kV/mm

ASTM D149

Dry: Comparative Tracking Index

600 V

IEC 60112

Processing


Nominal Value

Drying Temperature<Injection>


80 °C

Drying Time<Injection>


2.0 - 4.0 hr

Suggested Max Moisture<Injection>


0.15 %

Processing Temp, Melt<Injection>


240 - 285 °C

Mold Temperature<Injection>


65 - 80 °C

Injection Pressure<Injection>


3.50 - 12.5 MPa